
Add to Cart
Pulse Reverse power supplies- pulse and pulse reverse DC power supplies
Output power: max. 6360 Watts
Effective - and DC-current: max. 318 A
Pulse current: max. 720 A
Effective voltage: max. 500 V
Output power: max. 6360 Watts
Effective - and DC-current: max. 318 A
Reverse-current: max. 720 A
Effective voltage: max. 500 V
Typical applications:
PCB lines
Pulse plating
Reel-to-reel plating
Characteristic values
Switch mode technology
Single or Dual output available
Linearity inaccuracy < 1 % (related to nominal DC value)
Ripple less than < 1 % (related to nominal DC value)
Complex waveforms
Constant current regulation (voltage regulation on request)
SPI interface for control unit pe8005
Fast rise and fall times (rectangular waveforms)
Permanent short circuit and open circuit proof
Microprocessor controlled regulation
Mains supply: standard 3x380 V - 460 V +/- 10 % / 50-60 Hz (other voltage on request)
Max. effective output power: 1x 6360 Watts or 2x 3180 Watts
Cooling
Air cooled, air consumption max. 510m3/h Ambient temperature 35°C (other on request) Over temperature protected
Design
Compact 19“ unit; protection grade IP21
Stainless steel casing
Aluminium front panel
DC/Pulse connection in back panel (high voltage clamps)
Dimensions (W x H x D): 483 x 179 x 520 mm
For Example
Type | DA-6-159-360-D other sizes on request |
Effective current / DC | 2 x 159 A |
Forward pulse | 2 x 360 A |
Reverse pulse | 2 x 360 A |
Effective voltage | 2x 6 V |
Mains supply | 3 x 400 V AC |
Cooling | air cooled via three fans |
Cooling air consumption | 510 m3/h |
Dimensions | 483 x 178 x 620 (W x H x D) |
Weight | approx. 45 kg |
Operation / programming (via external pe8005 control unit)
Large illuminated 5,7“ graphic display
5 x 4 keypad for easy handling and navigation
Clear and user friendly menu navigation via well structured pull down menus
Easy generation of complex waveforms with up to 16 individual steps with 2 individual amplitudes (Ix1 and Ix2 as well as tx1 and tx2), that can be positive or negative
MMC/SD card reader for software update, import / export of device configuration, set values and storing of bus-logging data
Synchronization function
2 programmable output relays
Ah-totalizer, dosage counter, timer
Programmable START ramp
Parameters individually adjustable even during operation
Display
Clear display of actual values
Graphic view of the set value shape, actual values shown in oscilloscope- mode
Status, warning and error indication
Resolution
0 up to +/- xx.xA for Ix1 and Ix2; resolution: 100mA
0 up to 9 999.9mSec for tx1 and tx2; resolution: 0,1mSec Cycles (repeatings per step): 1 - 99