Add to Cart
Pulse and pulse reverse DC power supplies - Plating electronic used in Electroplating Industry
Output power: max. 64000 Watts
Effective - and DC-current: max. 4240 A
Pulse current: max. 9600 A
Effective voltage: max. 6 V
Output power: max. 2 x 16000 Watts (max. 4 x 8000 Watts)
Effective - and DC-current: max. 2 x 1060 A (max. 4 x 424 A)
Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)
Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)
Typical applications:
PCB lines
Characteristic values
Switch mode technology
Dual output, 4-fold output (single output optional) (see below matrix)
Linearity inaccuracy < 1 % (related to nominal DC value)
Ripple less than < 1 % (related to nominal DC value)
Complex waveforms
Constant current regulation (voltage regulation on request)
SPI interface for control unit pe8005
Fast rise and fall times (rectangular waveforms)
Permanent short circuit and open circuit proof
Microprocessor controlled regulation
Mains supply: standard 380 V - 460 V/3~ +/- 10 % / 50-60 Hz Optional: 200 V - 240 V/3~ +/- 10 % / 50-60 Hz
Max. effective output power: see below matrix
Cooling
Water cooled (designed for the direct installation at the electroplating tank)
Ambient temperature 40°C
Over temperature protected
Design
Compact stainless steel casing; protection grade IP54
DC/Pulse connection in back panel (tin copper bus bars)
Type | pe80CD122 / pe80CD124 | pe80CD202 / pe80CD204 | pe80CD322 / pe80CD324* | pe80CD402 / pe80CD404* |
Forward current | 2 x 120 A / 4 x 120 A | 2 x 200 A / 4 x 200 A | 2 x 320 A / 4 x 320 A | 2 x 400 A / 4 x 400 A |
Reverse pulse current | 2 x 360 A / 4 x 360 A | 2 x 600 A / 4 x 600 A | 2 x 960 A / 4 x 960 A | 2 x 1200 A / 4 x 1200 A |
Current ratio IF : IR | free adjustable | |||
Effective current / DC | 2 x 159 A / 4 x 159 A | 2 x 265 A / 4 x 265 A | 2 x 424 A / 4 x 424 A | 2 x 530 A / 4 x 530 A |
Minimum time reverse-pulse | 0,1 msec. | |||
Water cooling | ||||
Max. water inlet temperature | 23 - 26°C | |||
Max. water outlet temperature | 40°C | |||
Water consumption approx. | 3 l/min (*3,6 l/min) |
Type | pe80CD442 | pe80CD482 | pe80CD522 | pe80CD602 |
Forward current | 2 x 440 A | 2 x 480 A | 2 x 520 A | 2 x 600 A |
Reverse pulse current | 2 x 1320 A | 2 x 1440 A | 2 x 1560 A | 2 x 1800 A |
Current ratio IF : IR | free adjustable | |||
Effective current / DC | 2 x 583 A | 2 x 636 A | 2 x 689 A | 2 x 795 A |
Minimum time reverse-pulse | 0,1 msec. | |||
Water cooling | ||||
Max. water inlet temperature | 23 - 26°C | |||
Max. water outlet temperature | 40°C | |||
Water consumption approx. | 3 l/min | 3,4 l/min |
Type | pe80CD642 | pe80CD722 | pe80CD762 | pe80CD802 |
Forward current | 2 x 640 A | 2 x 720 A | 2 x 760 A | 2 x 800 A |
Reverse pulse current | 2 x 1920 A | 2 x 2160 A | 2 x 2280 A | 2 x 2400 A |
Current ratio IF : IR | free adjustable | |||
Effective current / DC | 2 x 848 A | 2 x 954 A | 2 x 1007 A | 2 x 1060 A |
Minimum time reverse-pulse | 0,1 msec. | |||
Water cooling | ||||
Max. water inlet temperature | 23 - 26°C | |||
Max. water outlet temperature | 40°C | |||
Water consumption approx. | 3,7 l/min | 4,1 l/min | 4,4 l/min | 4,6 l/min |
Operation / programming
(via external pe8005 control unit)
Large illuminated 5,7“ graphic display
5 x 4 keypad for easy handling and navigation
Clear and user friendly menu navigation via well structured pull down menus
Easy generation of complex waveforms with up to 16 individual steps with 2 individual amplitudes (Ix1 and Ix2 as well as tx1 and tx2), that can be positive or negative
MMC/SD card reader for software update, import / export of device configuration, set values and storing of bus-logging data
RS485 interface (optional: PROFIBUS or TCP/IP) Synchronization function
2 programmable output relays
Ah-totalizer, dosage counter, timer Programmable START ramp
Parameters individually adjustable even during operation
Display
Clear display of actual values
Graphic view of the set value shape, actual values shown in oscilloscope-mode with real time oscilloscope-function
Status, warning and error indication
Resolution
0 up to +/- xx.xA for Ix1 and Ix2; resolution: 100mA
0 up to 9 999.9mSec for tx1 and tx2; resolution: 0,1mSec Cycles (repeatings per step): 1 - 99