Add to Cart
Air cooled DC Plating rectifiers-New Plating and Anodizing Rectifiers for Sale
DC rectifiers, Cabinet models
Cooling: Air cooled
DC-rectifiers. Floor mounted cabinet with switch mode technology, air-cooled
Current6 000 A
Power100 000 W
Voltage1 000 V
Output power: max. 80kW
DC current: max. 5000A (at 15V)
DC voltage: max. 1000V (at 80A)
Typical applications:
Chrome plating Anodizing/Aluminium colouring
Barrel plating Rack plating
Air cooled DC power supply in switch mode technology, designed for use in electroplating in compact design.
Variable output range
the output range can be individually multiplied
Characteristic values
Linearity inaccuracy:
- for amperage < 1 %
- for voltage < 0.5 %
Ripple less than < 2 %
Efficiency typical > 85 % Powerfactor cos φ 0,95
Constant current and voltage control Soft start function
Over temperature protection
Pulse operation optional
Mains supply: standard 3 x 380 V +/- 10 % / 50-60 Hz (other voltages on request)
Cooling
Air cooled, air consumption max. 2000m3/h
Ambient temperature 35°C (other on request)
Design
Compact Rittal TS cabinet; powder coated: IP20
Powder coated, RAL 7035
DC connector via DC output bus bars in the top of the cabinet
Values | Standard sizes - DC output1 1other sizes on request | |||||||||||
DC current | 5000 A | 4000 A | 3500 A | 3000 A | 2500 A | 80 A | ||||||
DC voltage | 4V | 5V | 6V | 8V | 10 V | 12 V | 15 V | 18 V | 20 V | 24 V | 30 V | 1000 V |
Mains supply | 3 x 380V AC | |||||||||||
Weight | approx. 300 kg |
Control
peRB interface
Analog signals Iset, Uset, Iact, Uact = 0-10 V
Control unit for the controlling of DC power supplies of
Designed for electroplating applications Large 3-line LCD-display, keypads for easy programing/selection
Current and voltage infinitely adjustable by UP / DOWN buttons
Current and voltage preset
Ampere-hour counter (totalizer) Protection grade: IP54
Ambient temperature max. 40°C
Optional available functions
Preset counter, dosage counter *
Ramp function (start / stop ramp)
Timer function for ON / OFF * Voltage / current alarm *
Operating hours counter
Chopper timer (pulse-capable rectifier type requested)
Pole changer function (mechanical / electronic) *
Programmable DC steps (14 individual steps) *
Extern ON
* Indication / alarm output
Control via: RS485, PROFIBUS, TCP/IP (other on request)